Re: Virtual Connect Domain Status Critical!!
HiThe first thing to do is to upgrade the VC firmware to the latest version, as you are running the latest OA 4.50. I belive this will resolve the issue.
View Article4 Flex-10 VC in one 7k Chassis?
Hi Forum, i would like to run 4 Flex-10 VC Module in a C7k Chassis, each in slot 1,2, 5 and 6 (in 3 and 4 is already an Broadcom FC Switch). Ive never seen an example, exept in slot 1,2,3 and 4. For...
View ArticleRe: Virtual Connect VMware vDS LLDP
ssh to the VCManager, use the following commands:show lldp <PortID>Xn for Uplink or dn for downlink, e.x. X2 or d16To enable network loop protection, use the set loop-protect command:>set...
View ArticleVC: Shared Uplink Sets: Status
Hi Guys,need your help with this, would you be able to explain what happened here? explain the status?Enet UplinkSet state FAILED : All ports DISCONNECTED_ENABLED, Previous: Enet UplinkSet state OK,...
View ArticleVC FF 20/40 and Stacking
We have (5) c7000 enclosures in (2) data centers, each is populated with VCE 1/10 modules (Bays 1 & 2) and VCF 4Gb modules (Bays 3 & 4) configured with Active (Bay 1)/SAN Fabric A (Bay 3) and...
View ArticleDoes VC FlexFabric 10Gb/24-port Module and Pass through module work within...
Customer setup is C7000 chassis originally with just a fully cabled pass through module for network. Now customer would like the below setup with recently bought VC FlexFabric 10Gb/24-port Module...
View ArticleRe: Does VC FlexFabric 10Gb/24-port Module and Pass through module work...
The network connections of the blades are hardwired to the interconnect bays.The the OA user guide for details.The LOMs are wired to bays 1 and 2, you need additional NICs in the blades to connect...
View ArticleRe: Removing a VC domain from a VCEM domain group
Hello,We have a large VCEM 7.3 implementation controlling around 80 enclosures. We have a two enclosure VC Domain group that we need to change physical networking while keeping services alive in one of...
View ArticleMoving VCEM to its own server?
We have a 7.3 VCEM server co-mingled with numerous heavy hitting SIM related processes on physical server. VCEM controls a large environment of c7000 enclosures. Due to performance and instability we'd...
View ArticleRe: VCEM Database Migration question
Gee.. another set of broken links from the hpe migration.
View ArticleRe: No management IP address for VC-FC modules
Hi,I have the same problem.the link is no longer available http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02540140you can help me?Thank youRoberto
View ArticleRe: VC Active Standby Issue
Hi!For A/A you should create trunk SUS using phisical port's form the same VC module. For example:bay 1 : X7bay 1 : X8Then you'll get...
View ArticleRe: VCEM Database Migration question
>another set of broken links from the HPE split h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c04109201
View Articlehaving multiple ethernet adapters in a server profile - not working
hi allwe would like to carve out additional nics in our server profiles so that we can seperate our management network from the remaining networks (vlans)we have 3 x C7000 chassis, running VC v...
View ArticleRe: having multiple ethernet adapters in a server profile - not working
ive also noticed that with the new configuration i cannot even ping the gateway... so theres definitely something wrong with the VC config.the nics are showing as UP
View ArticleRe: having multiple ethernet adapters in a server profile - not working
we may have found a bug in VC thats causing the issue... were investigating..
View ArticleVC Flex-10 Enet + RHEL 6 Network Bonding (LACP - 802.3ad)
Hello,is it possible to use LACP - 802.3ad (Mode 4) Network Bonding with VC Flex-10?Not for the Uplink Ports but for the Connection to the Blade Servers?!Got some Centos 6 Hosts with several Networks...
View ArticleVirtual Connect Domains and CDP Traffic
We are implementing a vRealize environment on our ESX Hosts and are having issues because the Virtual Connect Domain doesn't seem to be passing the Cisco Discovery Protocol (CDP) traffic through it....
View ArticleRe: having multiple ethernet adapters in a server profile - not working
Since this is an ESXi box, you will have to go into the ESXi console and enable the additional NIC's in the networmk configuration. If they are not checked as being enabledf, they will not show up on...
View ArticleRe: VC Active Standby Issue
For Active/Active you would create a SUS with multiple ports from I/O Module 1 and a SUS with multiple ports from I/O module 2. SUS_1 - encX:bay1:PortX2, PortX3...PortXnSUS_2 -...
View Article